charlottepipefoundry
charlottepipefoundry
  • Видео 39
  • Просмотров 885 425

Видео

#ThankEssentialWorkers
Просмотров 3904 года назад
We thank essential critical workers. #ThankEssentialWorkers #ThankAPlumber
#ThankAPlumber
Просмотров 7154 года назад
The President and U.S. Department of Homeland Security have deemed plumbers as “essential critical infrastructure workers.” We couldn’t agree more. #ThankAPlumber #ThankEssentialWorkers
How to Cut and Join 6 Inch and Larger ABS, PVC and CPVC
Просмотров 82 тыс.4 года назад
Get installation tips for large diameter plastic plumbing systems. Charlotte Pipe manufactures pipe and fittings from half inch to 16 inches.
Cast Iron Versus Plastics Plumbing System
Просмотров 15 тыс.4 года назад
Wondering whether to choose cast iron or plastics for your plumbing system. This video gives tips from a manufacturer of both materials.
How to Cut and Join ConnecTite, Push-Fit DWV Fitting - Full Version
Просмотров 2,5 тыс.4 года назад
ConnecTite is a push-fit DWV fitting for plumbing systems. This video gives tips for repairing your DWV plumbing system with a fitting that does not require solvent cement or primer. It is compatible with PVC and ABS pipe.
Installing Charlotte Pipe's ConnecTite - Brief version
Просмотров 2,2 тыс.4 года назад
ConnecTite is a push-fit DWV fitting. It provides a fast, simple way to repair DWV plumbing systems. It is not for pressure systems.
How to Cut and Join 1/2 to 4 inch ABS, PVC and CPVC
Просмотров 47 тыс.4 года назад
Tips for cutting and joining plastic pipe and fittings - ABS, PVC and CPVC.
How to Cut and Join FlowGuard Gold
Просмотров 22 тыс.4 года назад
Tips for cutting and joining FlowGuard Gold. FlowGuard Gold CPVC CTS is for hot and cold water distribution. It is energy efficient, with better heat retention and lower hot water heating costs as compared to metallic systems.
How to Cut and Join Cast Iron Soil Pipe
Просмотров 43 тыс.4 года назад
Get tips for joining cast iron soil pipe and fittings. Cast iron pipe and fittings have been the backbone of drain, waste and vent plumbing systems throughout the world for centuries.
Tips for Cutting and Joining ChemDrain Pipe and Fittings
Просмотров 1,2 тыс.4 года назад
Get tips for cutting and joining ChemDrain pipe and fittings. ChemDrain CPVC pipe and fittings are for chemical waste drain systems and offers a safe, durable, easy-to-install and economical alternative for institutional, academic and commercial laboratories.
Master Plumber Shares Experience with Chemical Waste Plumbing Systems
Просмотров 2,5 тыс.5 лет назад
A master plumber shares his experience with ChemDrain chemical waste plumbing systems versus other options.
How Your Plumbing Works
Просмотров 15 тыс.6 лет назад
Simple explanation of how indoor plumbing systems work. Covers pressure and drain-waste-vent (DWV) system and how they work together to provide safe, clean water into your home or building.
Thinking About Air Testing Your Plumbing System? Don't Do It.
Просмотров 4,1 тыс.6 лет назад
Why you shouldn't ever air test pvc pipe.
Air Testing Short 1
Просмотров 3 тыс.6 лет назад
There's no safe way to air test PVC pipe
Air Testing Short 2
Просмотров 6296 лет назад
Air Testing Short 2
Air Testing Short 3
Просмотров 4106 лет назад
Air Testing Short 3
Choosing a plumbing system for commercial kitchen
Просмотров 4,9 тыс.6 лет назад
Choosing a plumbing system for commercial kitchen
ConnecTite versus PVC Fitting Installation
Просмотров 102 тыс.7 лет назад
ConnecTite versus PVC Fitting Installation
ConnecTite - The First Push-fit DWV Fitting
Просмотров 20 тыс.7 лет назад
ConnecTite - The First Push-fit DWV Fitting
Why Choose ConnecTite
Просмотров 2,3 тыс.7 лет назад
Why Choose ConnecTite
Connectite versus other PVC fittings
Просмотров 2,4 тыс.7 лет назад
Connectite versus other PVC fittings
ConnecTite Only Human
Просмотров 59 тыс.7 лет назад
ConnecTite Only Human
Plumbing Pressure Test With Air
Просмотров 127 тыс.7 лет назад
Plumbing Pressure Test With Air
Helpful Guide to Making Your First Potato Gun
Просмотров 9 тыс.7 лет назад
Helpful Guide to Making Your First Potato Gun
Air Testing Your Plumbing System Guidelines
Просмотров 7 тыс.7 лет назад
Air Testing Your Plumbing System Guidelines
Charlotte Pipe and Foundry Company, Our Culture and History
Просмотров 28 тыс.8 лет назад
Charlotte Pipe and Foundry Company, Our Culture and History
Measuring Sound in PVC and Cast Iron DWV Plumbing Systems
Просмотров 20 тыс.8 лет назад
Measuring Sound in PVC and Cast Iron DWV Plumbing Systems
Value Engineering
Просмотров 6 тыс.9 лет назад
Value Engineering
How A Plumbing System Works
Просмотров 192 тыс.9 лет назад
How A Plumbing System Works

Комментарии

  • @skylerbabcock7891
    @skylerbabcock7891 4 дня назад

    how exactly would you do a multi level building floor by floor? Not certain you can water test that way. What's our options then?

  • @adamnein9085
    @adamnein9085 20 дней назад

    I've been air testing cpvc up to 100 psi for years. Never any explosions, just dry fits popping apart

  • @_Joker_66
    @_Joker_66 23 дня назад

    Can I get a job in your company?

  • @JohnQPublic345
    @JohnQPublic345 Месяц назад

    im doing a commercial drain pipe- 1.5" line to a sink, tying into existing 2" cast iron drain. would it be up to code to use PVC schedule 40, or is it a local code I'd need to check?

  • @CC-ip3ve
    @CC-ip3ve Месяц назад

    Especially with 50000psi 🤦‍♂️

  • @CopeBUILT
    @CopeBUILT Месяц назад

    I wonder what happens if I dense pack the stud bay with cellulose or roxul rock wool

  • @cameragirl242
    @cameragirl242 3 месяца назад

    Oo. Just poured boiling water down kitchen sink drain several times after using enzymatic drain cleaner.

  • @jovanibedolla9899
    @jovanibedolla9899 4 месяца назад

    What bevel tool did you use?

  • @man-observing-world
    @man-observing-world 4 месяца назад

    “Can get somebody keeled” - Said a man with safety goggles

  • @frankjwell
    @frankjwell 5 месяцев назад

    Great

  • @jaimeleon1535
    @jaimeleon1535 7 месяцев назад

    So I’m currently installing a new black steel compressed air line. It just so happens that the existing line the customer is using is all pvc. I’m not allowed to shut off the air due to the business still being operational. How worried should I be about this happening?

  • @alanwhite933
    @alanwhite933 7 месяцев назад

    I sure wish the Dowds would embrace the old Gold mines on the property and create some kind of mini museum for tourists and even local residents to understand some of the history, literally, in their backyard. Probably one of the last chances to do so before everything gets built over.

  • @vertihvost7675
    @vertihvost7675 8 месяцев назад

    This is not for pressure application. Only for drains

  • @parkerswafford1151
    @parkerswafford1151 9 месяцев назад

    Got to tour the old cast iron plant in downtown charlotte! Awesome experience. Hope to see the new one!

  • @stephenbrickwood1602
    @stephenbrickwood1602 9 месяцев назад

    Excellent work 👏 I still have pvc, so what do I do? MLV maybe.

  • @tasaduqhussain3743
    @tasaduqhussain3743 9 месяцев назад

    nonsense i have an air tester rated at 3 bar test and 6 bar test for plastic. there are two prv for safety, JG plastics can withstand at least 30 bar so do the math and get a kit like mine before passing such a severe judgment.

  • @Shortbus-productions
    @Shortbus-productions 11 месяцев назад

    you pissed me off, I want to build it more

  • @jesusisking4953
    @jesusisking4953 Год назад

    Idk a little sketched out by it. The option to swivel the pipe is interesting.

  • @mystiqkc
    @mystiqkc Год назад

    Nice video. Thanks!

  • @nickgamble4544
    @nickgamble4544 Год назад

    Lol remove excess. I'm adding more cement to.the joint after I set it in

  • @keifla12
    @keifla12 Год назад

    I love that this was the standard for years when I was a plumber 😂

  • @denovillerslaurent2950
    @denovillerslaurent2950 Год назад

    cAST IRON CAST IRON cAST iRONNNNNNNNNN

  • @congcodei9392
    @congcodei9392 Год назад

    Psas hadir

  • @jeremycleary2002
    @jeremycleary2002 Год назад

    I like your message, but I’m building one anyway 🤣

    • @Lesr8
      @Lesr8 4 месяца назад

      same here

  • @paul_london
    @paul_london Год назад

    Rotten cast iron is the worst, PVC all the way please.

  • @flipnasty2296
    @flipnasty2296 Год назад

    Both need to be licensed/certified and continued education (apprentice) just to be able to work.... Obviously a lot more schooling education knowledge etc to be a dr

  • @flipnasty2296
    @flipnasty2296 Год назад

    Measure....cut (Sawzall).... primer...glue.... next

  • @xarmanhsh2981
    @xarmanhsh2981 Год назад

    how about black steel pipe ? is there a way to add colour air so we can see the leak?

  • @austinwerrmann1679
    @austinwerrmann1679 Год назад

    My plumber doesn’t test with water he doesn’t test with air either. Actually he test with a lack of air. He puts a vacuum on it to get negative pressure.

  • @MB2NDN
    @MB2NDN Год назад

    Lmao @ square cut with hacksaw

  • @MB2NDN
    @MB2NDN Год назад

    I love the idea of this but who takes that long to cement a pipe joint like that? Also who in the field is going to wear gloves. You don’t have to over exaggerate the process to sell connect tite, I would buy right now if it were available in my municipality

  • @xVicissitudesx
    @xVicissitudesx Год назад

    At :53 seconds on the video, what is that type of a reamer called? And who manufactures it if you don't mind?

  • @cris2068
    @cris2068 Год назад

    Great video guys!

  • @joseartiaga3048
    @joseartiaga3048 Год назад

    You can test waste with air not water pressure pipe

  • @nareshsculpture.6231
    @nareshsculpture.6231 Год назад

    How many psi?

  • @Summerstorm95
    @Summerstorm95 Год назад

    What is the deburring tool used on the plastic pipe?

  • @HeinekenSkywalker636
    @HeinekenSkywalker636 Год назад

    Can’t wait until this junk goes out of business. Do not use this stuff unless you have to it sucks and no one trusts it

  • @JustJanitor
    @JustJanitor Год назад

    This looks awesome

  • @joshuajohnson1036
    @joshuajohnson1036 Год назад

    Why? Stupid to me?

  • @geeess6353
    @geeess6353 Год назад

    Can the fittings spin after connected like a shark bite? Or does it stay in a fixed position like glue?

  • @wiitele
    @wiitele Год назад

    "Or I'll find you find you" is the part that made me make the vow not to ever do this.

  • @64mikecowart
    @64mikecowart Год назад

    If you really want it to last a long time dab some Permatex or tar on the cut ends before inserting them into the rubber so the cast iron is waterproofed like it’s supposed to be. Every time I take an old cast iron pipe out the ground or ceiling it’s degraded at the bottom of couplings

  • @conqwiztadore2213
    @conqwiztadore2213 Год назад

    Can you use 2 pieces of 48" of 4x4 sandwiched together like this -II- and a sledge hammer to hammer a full length 8" pipe into the hub? Or will the wood just absorb the blow and now push the pipe in? Anyone try this before?

    • @whitewolf1298
      @whitewolf1298 Год назад

      Yes, it will work so long as you keep the pipe level with the fitting. You have to be sure that the fitting is secure and will not move as you pound the pipe into place by bracing the back of it with some wood scraps or something similar. The best thing to use as a buffer is a square piece of 2 x 12 or several layers of 3/4" plywood that totally covers the pipe so that the specific impulse of each blow is distributed across the entire pipe surface. Needless to say, everything has to be done quickly. The solvent for PVC pipe cement is acetone and the stuff evaporates like nobody's business. The cement will start to set up in about 45 seconds. (less on hot dry days.)

  • @shanonquinn5681
    @shanonquinn5681 Год назад

    Unfortunately, the state of Idaho REQUIRES pressure testing of PVC plumbing for rough in inspection. Belive me, I don't want to. I am curious, though, does pressure testing (in addition to being dangerous) damage the solvent welded joints? Our glue on test caps have failed. I am having all manner of problems.

  • @TrueHelpTV
    @TrueHelpTV Год назад

    Hey Charlotte Pipe, in the spirit of safe science, excluding the external factors mentioned like temperate, and general atmospheric pressure, were these demonstrated failures roughly around or above the rated psi on the pipe?

  • @surekhasambyal3366
    @surekhasambyal3366 Год назад

    Pagl in san

  • @randomdude3066
    @randomdude3066 2 года назад

    Quarter turning 4 inch PVC is extremely difficult.

  • @labmanme
    @labmanme 2 года назад

    great advice,,,,thanks

  • @travisyarbrough4033
    @travisyarbrough4033 2 года назад

    So the company that makes 1950's products is trying to say that cast iron should still be used ???? Ha !!!! PVC won't rot or rust soooooo ........ Bye Bye rotten cast iron !!!!

    • @cristianmunoz2480
      @cristianmunoz2480 Год назад

      Yeah PVC in a high rise building is such a brilliant idea. In case of a fire the people will pass out due to the poisonous fumes off the PVC. There's a reason why Cast Iron is still used.

  • @Pskawt
    @Pskawt 2 года назад

    Thanks bro. I’m surprised by how many people still do this even after it’s explained to them, shown how it’s not approved by code or manufacturer specs. Some people never learn.